AC BTU Calculator

Size a room air conditioner in BTU/h from floor area, ceiling height, sun, occupants and appliance heat, with a raw figure and one rounded up to a unit size.

AC BTU Calculator

Recommended cooling capacity (BTU/h)
7,282.5
The unrounded cooling-capacity estimate in BTU per hour: the sun-adjusted load plus occupant and appliance heat.
Room floor area
270
Ceiling-height adjusted base BTU/h
6,075
Sun-adjusted BTU/h
6,682.5
Occupant adjustment (BTU/h)
600
Rounded recommended AC size (BTU/h)
7,500
Room-AC range check
The rounded size of 7,500 BTU/h is inside the 5,000–24,000 BTU/h range of usual room air conditioners.

Background.

Standing in a shop aisle between a 6,000 and an 8,000 BTU window unit, most people pick the bigger one to be safe. It is often the wrong instinct. An air conditioner that is too small runs flat out all afternoon and never quite catches up, but one that is too large chills the air in a few minutes and switches off before it has pulled much moisture out, leaving a room that is cold and clammy at once, and it costs more to buy.

The usual starting point is a rule ENERGY STAR has long published: about 20 BTU per hour for each square foot of floor, then adjusted for the room. Its guidance raises capacity by 10% for a very sunny room and lowers it by 10% for a heavily shaded one, adds 600 BTU per hour for each person beyond two who regularly uses the room, and adds 4,000 BTU per hour if the room is a kitchen. The estimate here follows the same pattern and also scales for ceiling height, so an 18 by 15 foot room with a 9-foot ceiling, some sun and three regular occupants comes to 7,282.5 BTU per hour, rounded up to a 7,500 BTU unit.

It is a buying estimate for a single room, not a load calculation. Insulation, air leakage, window area and glazing, which way the walls face, your climate and how humid the air is all change the true cooling load, and none of them is modelled. For central air or a whole house, a professional Manual J calculation is the tool; for choosing a window, through-wall or portable unit, a clear rule of thumb applied carefully gets most rooms close.

What is ac btu calculator?

A BTU, or British thermal unit, is the heat needed to warm one pound of water by one degree Fahrenheit, about 1,055 joules. Air conditioners are rated in BTU per hour, the rate at which they can remove heat from a room under standard test conditions; that rate is the unit's cooling capacity. One BTU per hour is about 0.293 watts, so a 7,500 BTU unit removes heat at roughly 2.2 kilowatts, and 12,000 BTU per hour is the 'ton' used for larger systems, the cooling once supplied by melting a ton of ice over a day.

The heat a unit has to remove comes in two forms. Sensible heat raises the temperature — sun through the glass, warm walls, people, appliances. Latent heat is the moisture in the air, which the unit removes by condensing it on its cold coil. A correctly sized unit runs long enough to do both; a much larger one satisfies the thermostat on sensible heat alone and leaves the humidity behind, which is why the right size is a target rather than a minimum to exceed.

Room units are generally sold from about 5,000 to 24,000 BTU per hour. A room that needs more than the top of that range is better served by a split system or more than one unit.

How to use this calculator.

  1. Measure the room's length and width in feet, wall to wall. For an L-shaped room, work out the total floor area and enter two dimensions that multiply to it — 20 × 13.5 for 270 square feet, for example.
  2. Enter the ceiling height. The calculation treats 8 feet as standard, so a taller ceiling raises the estimate in proportion and a lower one reduces it.
  3. Keep the base at 20 BTU per square foot unless you have a reason to change it — raise it for a top-floor room under a hot roof. For a heavily shaded room enter −10 in the sun field, ENERGY STAR's 10% reduction.
  4. Set the sun adjustment as a percentage (10 for a very sunny room, 0 for an ordinary one, −10 for a heavily shaded one), enter how many people regularly use the room, and add appliance heat in BTU per hour: 4,000 for a kitchen, or the wattage of other equipment × 3.412.
  5. Choose a rounding increment that matches the sizes on sale, usually 500 or 1,000, then read the raw estimate and the rounded size and shop for a unit at the rounded figure, not far above it.

The formula.

BTU = A × b × (h⁄8) × (1 + s) + O + E

BTU/h = A × b × (h ÷ 8) × (1 + s ÷ 100) + O + E. A is the floor area in square feet, b the base BTU per square foot, h the ceiling height in feet, s the sun adjustment as a percentage, O the occupant heat and E the appliance heat. O = max(0, people − 2) × the extra BTU per additional occupant, so the first two people are already assumed in the base rule and only the third and later add heat. The result is then rounded up — never down — to the next multiple of the chosen increment.

The order of operations matters. The ceiling factor and the sun percentage multiply the area-based load, while occupants and appliances are added afterwards at their full values. A 20% sun adjustment therefore grows a large room's estimate by far more than a small room's, but a kitchen's 4,000 BTU is the same 4,000 whatever the room size.

Two simplifications are worth knowing. Scaling the whole load by h ÷ 8 assumes heat gain grows in step with ceiling height; in reality much of the load comes through windows and the roof, which do not grow with the walls, so a 12-foot ceiling's factor of 1.5 can overstate a tall room with little glass. And the base rule bundles the building's insulation, airtightness and climate into one number per square foot, which is why it can be adjusted. What changes the answer most in practice is the area and the base rate: every extra 50 square feet at 20 BTU adds 1,000 BTU per hour before any multiplier.

A worked example.

Example

The example room is 18 feet by 15 feet, so area is 270 square feet. The base sizing assumption is 20 BTU per square foot, giving 270 × 20 = 5,400 BTU per hour. The ceiling is 9 feet high, so the ceiling factor is 9 ÷ 8 = 1.125, and 5,400 × 1.125 = 6,075 BTU per hour. The room gets strong afternoon sun, so a 10 percent increase applies: 6,075 × 1.10 = 6,682.5 BTU per hour. Three people regularly use it, one more than the two built into the base rule, which adds 600 BTU per hour. The raw recommendation is 6,682.5 + 600 = 7,282.5 BTU per hour, and rounded up to the nearest 500 the size to shop for is 7,500 BTU per hour. In other units that is about 2.2 kilowatts of cooling, or 0.625 of a ton. It also sits just above ENERGY STAR's own sizing table, which lists 7,000 BTU per hour for rooms of 250 to 300 square feet before any adjustment — the 9-foot ceiling, the sun and the third occupant account for the difference.

ceiling Height Ft9
btu Per Sq Ft20
extra Btu Per Additional Occupant600
room Width Ft15
sun Exposure Percent10
rounding Increment Btu500
room Length Ft18
appliance Btu0
occupants3

Frequently asked questions.

Why does my small bedroom come out below 5,000 BTU?
Because a small room needs very little. A 12 by 12 foot bedroom with an 8-foot ceiling, some sun and two occupants comes to 3,168 BTU per hour, rounded to 3,500. Room units are rarely made below about 5,000 BTU per hour, so the smallest model on sale is the right choice; it will cycle more than ideal, which is the trade-off of a very small room.
Why start from 20 BTU per square foot?
It is the rule of thumb ENERGY STAR has long given for room air conditioners: about 20 BTU per hour per square foot of living space, before adjustments. ENERGY STAR's own size table is more generous for small rooms — 7,000 BTU for 250 to 300 square feet, close to 26 BTU per square foot at 270 — so for a small, hot room a base slightly above 20 is reasonable. It is a screening rule, not a measured property of your room.
How do I allow for a heavily shaded room?
ENERGY STAR's guidance is to reduce capacity by 10% for heavy shade, and the sun field accepts negative values for exactly this case: enter −10 for a heavily shaded room and the load is cut by 10%. For the worked example's room that gives 6,067.5 BTU per hour, rounded to 6,500 rather than 7,500.
What goes wrong if the unit is too big?
It short-cycles. A much larger unit cools the air to the thermostat setting quickly and shuts off before its coil has removed much moisture, so the room feels cold yet damp, temperature swings more, and the frequent starts are less efficient. It also costs more to buy and may need a bigger electrical circuit. Rounding up to the next size is sensible; jumping two or three sizes above the estimate is not.
How do I count a kitchen, computers or other heat sources?
For a kitchen, ENERGY STAR adds 4,000 BTU per hour; enter that as the appliance adjustment. For other equipment, convert its power draw: each watt running continuously releases about 3.412 BTU per hour, so a 400-watt computer and monitor adds roughly 1,365 BTU per hour. The worked example's room used as a kitchen would need 11,282.5 BTU per hour, rounded to 11,500.
How much does a high ceiling change the size?
In direct proportion to the height over 8 feet. The example room needs 7,282.5 BTU per hour with a 9-foot ceiling, 8,025 with 10 feet and 9,510 with 12 feet. Because real heat gain does not rise as steeply as volume when the extra wall is plain and shaded, very tall rooms with little glass may need a little less than this suggests.
Is a portable unit's BTU rating comparable with a window unit's?
Not always. Portable air conditioners in the United States now carry a seasonally adjusted cooling capacity, SACC, measured under the Department of Energy's test procedure, alongside or instead of the older, higher figure. Single-hose portables in particular lose part of their output to the warm air they draw in from outside the room, so compare a portable's SACC with the estimate here, not its headline number.
How much electricity does a 7,500 BTU unit use?
Divide the capacity by the unit's energy efficiency ratio, which is BTU per hour of cooling per watt of power. At an EER of 11, a 7,500 BTU unit draws about 682 watts while the compressor runs. Eight hours of continuous running at that draw is about 5.45 kWh, roughly $0.98 at $0.18 per kWh; in practice the compressor cycles on and off, so a well-sized unit uses less. The label's combined efficiency ratio, CEER, also counts standby power, and a higher figure means lower running costs for the same cooling.
Is this the same as central AC sizing?
No. Central systems should be sized with a full load calculation such as Manual J, which accounts for the whole building envelope, ducts, air leakage, humidity, window area and glazing, insulation, orientation and local design temperatures. This estimate is a screening tool for one room and one room unit; using it for ducted, whole-home equipment would ignore most of what determines that load.
When should I not rely on this estimate?
For server rooms, commercial kitchens, laboratories, grow rooms, medical spaces or anywhere with strict humidity requirements, where the internal heat dwarfs the room rule and the consequences of getting it wrong are larger. An installer's assessment is also worth having where the electrical supply, window fit, ventilation or building rules limit what can be fitted.

How this page was produced

Published by
Quanta Calculator
Primary sources
5 cited below
Method
BTU = A × b × (h⁄8) × (1 + s) + O + E