Snow Load Calculator

Design roof snow load to ASCE 7-16: flat roof pf, sloped roof ps, the minimum load, and the total weight on your roof. Balanced case, every factor shown.

Snow Load Calculator

This is site-specific and is never assumed for you. Get it from the ASCE Hazard Tool at ascehazardtool.org or from your building department. Across much of the mountain west ASCE 7 designates "case study" regions where no map applies and the jurisdiction publishes its own value.
psf
Terrain category
Roof exposure
Thermal condition
Risk category
Enter 0 for a flat roof. Snow slides off a steep roof, so the slope factor Cs reduces the load above a threshold that depends on the thermal condition and the surface, reaching zero at 70 degrees.
in / 12
Roof surface
The HORIZONTAL projected area — the building footprint under the roof, not the sloped surface area. Snow load is defined on the horizontal projection, so using the sloped area would overstate the total weight.
sq ft
Design roof snow load
28
The larger of the sloped roof snow load ps and, on a roof shallower than 15°, the §7.3.4 minimum pm. This is the BALANCED case only: it excludes unbalanced and drifted snow (§7.6–§7.8), sliding snow (§7.9), rain-on-snow surcharge (§7.10) and ponding (§7.11), any of which can govern and none of which this page computes. It implements ASCE/SEI 7-16 Chapter 7, the edition referenced by IBC 2021 and IRC 2021 — ASCE 7-22 changed the procedure and is not implemented here. Local amendments govern, adopted code editions differ between jurisdictions, and a licensed structural engineer must confirm the design snow load and sign off before work proceeds.
Which case governs
The sloped roof snow load ps governs at 28 psf. The §7.3.4 minimum does NOT apply, because the roof slope of 26.57° is at or above the 15° low-slope limit.
Factors, edition and what is not included
EDITION: this page implements **ASCE/SEI 7-16 Chapter 7**, the edition referenced by IBC 2021 and IRC 2021. pf = 0.7 × Ce × Ct × Is × pg (Eq. 7.3-1) and ps = Cs × pf (Eq. 7.4-1). FACTORS USED: Ce = 1 from Table 7.3-1 for Terrain Category C — open terrain with scattered obstructions with a partially exposed roof; Ct = 1 from Table 7.3-2 for a normally heated structure; Is = 1 from Table 1.5-2 for Risk Category II; Cs = 1 from Figure 7.4-1, which holds at 1.0 up to 30° for this combination of thermal factor and surface and falls linearly to 0 at 70°. GROUND SNOW LOAD: pg = 40 psf is YOUR input and is never assumed. Get it from the ASCE Hazard Tool or from your building department; across much of the mountain west ASCE 7 designates "case study" regions where the jurisdiction publishes its own value and no map applies. ASCE 7-22 IS DIFFERENT and this page does not implement it: 7-22 publishes ground snow loads per risk category so Is is no longer a multiplier in Eq. 7.3-1, retrieves pg from the ASCE Hazard Tool rather than a map, takes Ct for heated structures from a new R-value-based Table 7.3-3, and changed the form of the minimum load. If your jurisdiction is on IBC 2024 you need the 7-22 procedure, not this page. BALANCED LOAD ONLY: this is the balanced case. It does NOT include unbalanced or drifted snow (§7.6–§7.8), sliding snow (§7.9), rain-on-snow surcharge (§7.10), ponding (§7.11), or snow at projections and parapets. On a gable roof the unbalanced case often governs the members near the ridge, and a drift against a taller adjacent wall can be several times the balanced load — both are separate calculations. THE SNOW DEPTH shown is indicative only: it divides the design load by the ASCE Eq. 7.7-1 density γ = 0.13pg + 14 = 19.2 pcf, capped at 30 pcf, which is the density the standard prescribes for DRIFT calculations rather than a measured depth. Real snow ranges from about 5 pcf fresh to over 30 pcf when old and wet, so do not use this figure to judge what is on your roof right now. CODE AND SIGN-OFF: local amendments govern and adopted code editions differ between jurisdictions. A licensed structural engineer must confirm the design snow load and sign off before work proceeds.
Sloped roof snow load, ps
28 psf
Flat roof snow load, pf
28 psf
Minimum roof snow load, pm
20 psf
Exposure factor, Ce
1
Thermal factor, Ct
1
Snow importance factor, Is
1
Slope factor, Cs
1
Roof slope
26.5651°
Slope where Cs starts to fall
30°
Total snow weight on the roof
42,000 lb
Snow density, γ
19.2 pcf
Indicative snow depth
17.5 in

Background.

The number people usually have is the ground snow load, and the number they need is the roof snow load. Those are not the same, and the gap between them is the whole subject of ASCE 7 Chapter 7.

The conversion starts with a flat 30 percent reduction. A roof holds less snow than the ground beside it, because wind scours it, because heat leaks up through it, and because the ground snow load is itself a 50-year statistical value measured in a sheltered clearing. Equation 7.3-1 puts that as pf = 0.7 × Ce × Ct × Is × pg. So a 40 psf ground snow load in ordinary open terrain on a normally heated house becomes a 28 psf flat roof snow load before slope is considered at all.

Then three factors adjust it. The exposure factor Ce, from Table 7.3-1, is the biggest lever on the page: it runs from 0.7 for a fully exposed roof above the treeline to 1.2 for a sheltered roof in wooded suburban terrain, a 71 percent spread. Wind blows snow off an exposed roof and dumps it around a sheltered one, and the same 40 psf ground load gives 22.4 psf in Terrain D fully exposed and 33.6 psf in Terrain B sheltered. The thermal factor Ct, from Table 7.3-2, runs 0.85 for a heated greenhouse through 1.0 for a normal house, 1.1 for a cold ventilated roof, 1.2 unheated, up to 1.3 for a freezer building. The snow importance factor Is, from Table 1.5-2, is 0.8 for a low-hazard farm building, 1.0 for a house, 1.1 for a school and 1.2 for a hospital.

Slope comes last, and it is not linear. The slope factor Cs holds at exactly 1.0 up to a threshold and then falls in a straight line to zero at 70 degrees, and the threshold depends on two things at once: the thermal factor, which picks one of three graphs in Figure 7.4-1, and whether the surface is an unobstructed slippery one. For a warm roof the threshold is 5 degrees if slippery and 30 degrees otherwise; at Ct 1.1 it is 10 and 37.5; at Ct 1.2 or above it is 15 and 45. That is why a 6:12 asphalt-shingled roof gets no slope reduction at all — 26.6 degrees is below the 30 degree threshold — while the identical roof in standing-seam metal drops to Cs 0.668 and sheds a third of its load. It is also why a cold ventilated slippery roof at 12:12 comes out at 12.8 psf where the shingled warm version comes out at 28.

One provision catches people out. On a low-slope roof — monoslope, hip or gable shallower than 15 degrees — Section 7.3.4 imposes a minimum uniform load of Is × pg where the ground snow load is 20 psf or less, and Is × 20 psf where it is more. With a 15 psf ground snow load on a flat roof, Equation 7.3-1 gives 10.5 psf but the minimum gives 15, so 15 governs. The minimum is a separate load case, checked on its own and not combined with unbalanced or drift loading, and it stops a light-snow region from designing a flat roof for almost nothing. Above 15 degrees it does not apply at all, and the crossover between the two on a flat Risk II roof falls at a ground snow load of 28.6 psf.

This page computes the BALANCED case, and that limit matters more than any other caveat here. It does not compute unbalanced snow on a gable roof, which frequently governs the design of the members near the ridge; it does not compute drift against a taller adjacent wall or a parapet, which can be several times the balanced load; and it does not compute sliding snow onto a lower roof, rain-on-snow surcharge or ponding. Every one of those is a separate calculation in Sections 7.6 through 7.11, and a roof designed only for the balanced load is not designed.

The edition is ASCE/SEI 7-16, which is what IBC 2021 and IRC 2021 reference. ASCE 7-22 changed this procedure substantially and is deliberately not implemented: 7-22 publishes ground snow loads per risk category, so the importance factor is no longer a multiplier in Equation 7.3-1; the ground snow load is retrieved per site from the ASCE Hazard Tool rather than read off a national map; the thermal factor for heated structures now comes from a new Table 7.3-3 keyed on roof R-value and ground snow load; and the minimum load changed form and gained a cap. Implementing half of that from memory would produce a confidently wrong design load, so the page states the edition it implements and tells a reader on IBC 2024 that they need the 7-22 procedure instead.

The ground snow load itself is your input and is never assumed for you. Get it from the ASCE Hazard Tool or from your building department, and note that across much of the mountain west ASCE 7 designates case-study regions where no map applies and the local jurisdiction publishes its own value. Local amendments govern, adopted editions differ between jurisdictions, and a licensed structural engineer must confirm the design snow load and sign off before work proceeds.

What is snow load calculator?

The design roof snow load is the uniform downward pressure, in pounds per square foot of horizontal projection, that a roof must be designed to carry from accumulated snow. It is derived from the ground snow load at the site rather than measured on the roof.

ASCE 7-16 builds it in three steps. First, Equation 7.3-1 converts the ground snow load pg to a flat roof snow load pf = 0.7 × Ce × Ct × Is × pg, where Ce accounts for wind exposure, Ct for heat flow up through the roof and Is for the consequence of failure. Second, Equation 7.4-1 applies the slope factor: ps = Cs × pf, with Cs read from Figure 7.4-1 as a function of slope, thermal factor and surface slipperiness. Third, Section 7.3.4 imposes a minimum uniform load on low-slope roofs so that a light-snow region cannot design a flat roof for a trivial load.

Every one of those loads acts on the horizontal projection of the roof, not on the sloped surface. That is a convention worth remembering, because it means the roof area to use is the building footprint and not the shingle area — using the sloped area would overstate the total.

The balanced load is only the first of several cases. Sections 7.6 through 7.8 cover unbalanced and drifted snow, 7.9 sliding snow, 7.10 rain-on-snow surcharge and 7.11 ponding. On many roofs one of those, not the balanced load, sizes the members.

This calculator implements the balanced case of ASCE/SEI 7-16 Chapter 7. It does not compute drift, unbalanced, sliding, rain-on-snow or ponding loads, does not size any member, and does not implement ASCE 7-22.

How to use this calculator.

  1. Get the ground snow load for your site from the ASCE Hazard Tool or your building department, and enter it. Do not guess it — in case-study regions there is no map value and the jurisdiction publishes its own.
  2. Pick the terrain category from what is upwind of the building: B for urban, suburban or wooded, C for open country with scattered obstructions, D for flat unobstructed ground or water.
  3. Pick the roof exposure. Most roofs are partially exposed. Fully exposed means nothing shelters it on any side; sheltered means tight conifers or obstructions stand above roof level nearby.
  4. Pick the thermal condition. A normal heated house is 1.0. An unheated garage or open carport is 1.2, and a ventilated roof with more than R-25 between the vented space and the heated space is 1.1.
  5. Pick the risk category — II for houses and ordinary buildings.
  6. Enter the roof pitch as the rise per 12 inches of run, or 0 for a flat roof, and pick the surface. Unobstructed slippery means metal, slate, glass or membrane with nothing on it to catch snow; shingles and anything with vents or snow guards are "all other surfaces".
  7. Enter the horizontal projected roof area — the footprint, not the sloped surface — for the total weight.
  8. Read the design load, then read which case governs. If the minimum governs, your slope is under 15° and the ground snow load is low.
  9. Read the note beside the answer before using the number, especially the list of load cases this page does not compute. Then have a licensed structural engineer check the drift, unbalanced and sliding cases, which often govern.

The formula.

pf = 0.7·Ce·Ct·Is·pg · ps = Cs·pf · pm = Is × min(pg, 20) [slope < 15°]

Three equations and four factors. The flat roof snow load is pf = 0.7 × Ce × Ct × Is × pg (Eq. 7.3-1), where the 0.7 is the ground-to-roof conversion, Ce comes from Table 7.3-1 on terrain and exposure, Ct from Table 7.3-2 on thermal condition, and Is from Table 1.5-2 on risk category. The sloped roof snow load is ps = Cs × pf (Eq. 7.4-1). The slope factor comes from Figure 7.4-1: Cs = 1 for a slope θ at or below a threshold A, Cs = 1 − (θ − A) ÷ (70 − A) between A and 70 degrees, and Cs = 0 at 70 degrees and above. A is 5° for a warm roof with an unobstructed slippery surface and 30° otherwise; 10° and 37.5° when Ct is 1.1; and 15° and 45° when Ct is 1.2 or more. The minimum is pm = Is × pg where pg ≤ 20 psf and Is × 20 psf above that (§7.3.4), and it applies only where the slope is under 15 degrees. Working the example: pg = 40 psf, Terrain C partially exposed gives Ce = 1.0, a normally heated house gives Ct = 1.0, Risk Category II gives Is = 1.0, so pf = 0.7 × 1.0 × 1.0 × 1.0 × 40 = 28.0 psf. The 6:12 pitch is arctan(6 ÷ 12) = 26.565 degrees; the roof is warm with asphalt shingles, so A = 30 degrees, and 26.565 is below 30, so Cs = 1.0 exactly and ps = 28.0 psf. The slope is above 15 degrees, so the minimum of 1.0 × 20 = 20 psf does not apply, and the design load is 28.0 psf. Over a 1,500 sq ft footprint that is 42,000 pounds of snow. Change nothing but the surface to standing-seam metal and A drops to 5 degrees: Cs = 1 − (26.565 − 5) ÷ 65 = 0.6682 and the design load falls to 18.71 psf. The snow density from Eq. 7.7-1 is 0.13 × 40 + 14 = 19.2 pcf, capped at 30, which puts the 28 psf design load at an indicative 17.5 inches of snow — a scale check only, since real snow runs from about 5 pcf fresh to over 30 pcf old and wet. Every intermediate value is carried at twenty significant digits, rounding happens only at the final result, and the comparison between ps and pm that decides the governing case is made on the unrounded values.

A worked example.

Example

A 1,500 square foot house in a 40 psf ground-snow region, on open ground with scattered obstructions, normally heated, with a 6:12 asphalt-shingled roof. Terrain C with a partially exposed roof gives an exposure factor of 1.0, a normally heated structure gives a thermal factor of 1.0, and an ordinary house is Risk Category II, so the importance factor is 1.0 as well. The flat roof snow load is therefore 0.7 × 40 = 28.0 psf — the 30 percent ground-to-roof reduction doing all the work. The 6:12 pitch is 26.565 degrees. The roof is warm and shingled, which is an "all other surfaces" case, so the slope factor holds at 1.0 up to 30 degrees. At 26.565 degrees the roof is just inside that, so Cs is exactly 1.0 and there is no slope reduction at all. The design load stays at 28.0 psf. The slope is above 15 degrees, so the Section 7.3.4 minimum of 20 psf does not apply. Over the 1,500 square foot footprint that is 42,000 pounds of snow — twenty-one tons, which is the number most people find surprising. The indicative depth is 17.5 inches at the 19.2 pcf density Equation 7.7-1 prescribes. Three single-variable changes show where the sensitivity lies. Re-roof in standing-seam metal and nothing else changes, but the slope threshold drops from 30 degrees to 5, the slope factor falls to 0.668, and the design load falls to 18.71 psf — a third off, from the surface alone. Move the same house to Terrain B behind tight conifers and the exposure factor rises to 1.2, taking the flat roof load to 33.6 psf. Leave the building unheated instead, and the thermal factor of 1.2 does the same thing, 33.6 psf. And the load can go up rather than down. A 12:12 roof at 45 degrees on a freezer building sits exactly on its 45 degree threshold, so it gets no slope reduction either, while its thermal factor of 1.3 takes the flat roof load to 36.4 psf. Meanwhile a cold ventilated roof with a slippery surface at the same 45 degrees has a threshold of 10 degrees, a slope factor of 0.417, and a design load of 12.83 psf. Same slope, same site, nearly a factor of three between them. None of this is the whole design. The balanced load is one case; unbalanced snow on this gable roof, and any drift against a taller wall, are separate calculations that often govern.

roof Pitch Rise In6
risk Categoryii
thermal Conditionstandard
roof ExposurepartiallyExposed
roof Area Sq Ft1,500
surface Typeother
ground Snow Load Psf40
terrain Categoryc

Frequently asked questions.

Why is my roof snow load lower than the ground snow load?
Because Equation 7.3-1 starts with a flat 0.7 multiplier. A roof holds less snow than the ground next to it: wind scours it, heat leaking up through it melts the underside, and the ground snow load is itself a 50-year statistical value measured in a sheltered clearing. So a 40 psf ground snow load on an ordinary heated house in open terrain gives a 28 psf flat roof load before slope is even considered. The exposure, thermal and importance factors then push that up or down, and a sheltered unheated roof in a high-risk-category building can end up above the ground value.
Why doesn't my 6:12 roof get a slope reduction?
Because 26.565 degrees is below the threshold where the slope factor starts to fall. For a warm roof with an ordinary surface — asphalt shingles, wood shakes, or anything with vents or snow guards on it — Figure 7.4-1 holds Cs at 1.0 all the way to 30 degrees, which is a 6.93:12 pitch. Below that the code assumes nothing slides. Change the surface to unobstructed metal, slate, glass or membrane and the threshold drops to 5 degrees, at which point the same 6:12 roof gets Cs = 0.668 and sheds a third of its load.
What counts as an unobstructed slippery surface?
Metal, slate, glass or a membrane, with nothing on the roof to stop snow sliding off it — no vents, no snow guards, no ice-dam obstruction, no equipment. For a warm roof there is an extra condition: the roof also needs a thermal resistance of at least R-30 unventilated or R-20 ventilated, because a poorly insulated warm roof melts snow into a bonded layer rather than letting it slide. If any of that is not true, the roof is an "all other surfaces" case, and the difference in design load can easily be a third.
What is the minimum roof snow load and when does it apply?
Section 7.3.4 sets a floor on the design load for low-slope roofs — monoslope, hip and gable roofs shallower than 15 degrees, which is a rise of about 3.22 inches per foot. The floor is Is × pg where the ground snow load is 20 psf or less, and Is × 20 psf where it is more. With a 15 psf ground snow load on a flat Risk II roof, Equation 7.3-1 gives 10.5 psf while the minimum gives 15, so 15 governs. It is checked as a separate uniform load case and is not combined with unbalanced or drift loading. On a flat Risk II roof the crossover where the sloped load overtakes the minimum falls at a 28.6 psf ground snow load.
Does this include snow drift?
No, and that is the most important limit on this page. This is the balanced case only. ASCE 7-16 Sections 7.6 through 7.8 cover unbalanced and drifted snow, 7.9 sliding snow onto a lower roof, 7.10 rain-on-snow surcharge and 7.11 ponding, and none of them is computed here. The omissions are not academic: on a gable roof the unbalanced case frequently governs the members near the ridge, and a drift against a taller adjacent wall or a parapet can be several times the balanced load. A roof designed only for the balanced load is not designed. Have a licensed structural engineer run the other cases.
Why does the page implement ASCE 7-16 rather than 7-22?
Because 7-22 changed the procedure in four ways and one of them could not be sourced without guessing. In 7-22 the ground snow load is published per risk category and retrieved from the ASCE Hazard Tool rather than read off a national map, so the importance factor is no longer a multiplier in Equation 7.3-1; the thermal factor for heated structures comes from a new Table 7.3-3 keyed on roof R-value and ground snow load with interpolation permitted; and the minimum load changed form and gained a cap. Table 7.3-3 is the one that stops this page: inventing its values would produce a confidently wrong design load, which is worse than being explicit about the edition. ASCE 7-16 is what IBC 2021 and IRC 2021 reference. If your jurisdiction is on IBC 2024, you need the 7-22 procedure.
How much does the snow on my roof actually weigh?
For the worked example — 28 psf over a 1,500 square foot footprint — 42,000 pounds, or twenty-one tons. That is the design load rather than a measurement of today's snow, and it is a bigger number than most people expect, which is the point of showing it. Note that the load acts on the horizontal projection of the roof, so the area to use is the building footprint and not the shingle area; using the sloped area would overstate the total by the pitch factor.
How deep is the snow at my design load?
The page shows an indicative depth, but treat it with care. It divides the design load by the density Equation 7.7-1 prescribes, γ = 0.13 × pg + 14 capped at 30 pcf, which for a 40 psf ground snow load is 19.2 pcf and puts 28 psf at about 17.5 inches. That density is what the standard specifies for drift calculations, not a measurement. Real snow runs from roughly 5 pcf fresh and dry to over 30 pcf when it is old, settled and wet, so eight inches of one and four feet of another can weigh the same. Use the figure as a scale check on the design load, not to judge what is on your roof this morning.
Where do I get the ground snow load?
From the ASCE Hazard Tool at ascehazardtool.org, or from your building department. This page will not assume it for you, because it is genuinely site-specific and in some places genuinely not mapped: across much of the mountain west ASCE 7 designates "case study" regions where the elevation and terrain variation defeat a map, and the local jurisdiction publishes its own value. If two sources disagree, the value your jurisdiction has adopted is the one that governs.
Which factor should I be most careful about?
The exposure factor. It ranges from 0.7 for a fully exposed roof above the treeline to 1.2 for a sheltered roof in wooded suburban terrain, a 71 percent spread — wider than the thermal factor's range and wider than the importance factor's. The same 40 psf ground snow load gives 22.4 psf in Terrain D fully exposed and 33.6 psf in Terrain B sheltered. "Partially exposed" is the correct answer for most roofs and is what ASCE 7-16 assigns to everything that is not clearly one of the other two, so do not claim fully exposed unless nothing shelters the roof on any side.

References& sources.

  1. [1]American Society of Civil Engineers — ASCE/SEI 7-22, Minimum Design Loads and Associated Criteria for Buildings and Other Structures, Chapter 7 (Snow Loads). Cited as the edition this page does NOT implement, and as the source of the four changes named on the page: risk-category-specific ground snow loads retrieved from the ASCE Hazard Tool, the removal of Is from Eq. 7.3-1, the new R-value-based thermal factor Table 7.3-3 for heated structures, and the revised minimum load with its cap. Access is by purchase from ASCE; the chapter's provisions are gated to automated retrieval.
  2. [2]American Society of Civil Engineers — ASCE/SEI 7-16 Chapter 7, the edition implemented here and the one referenced by IBC 2021 and IRC 2021. Source of Eq. 7.3-1 (pf = 0.7 Ce Ct Is pg), Eq. 7.4-1 (ps = Cs pf), Table 7.3-1 exposure factor, Table 7.3-2 thermal factor, Table 1.5-2 snow importance factor, Figure 7.4-1 slope factor, §7.3.4 minimum roof snow load, and Eq. 7.7-1 snow density. Access is by purchase from ASCE and the provisions are gated to automated retrieval, so every table value shipped here was confirmed against at least two independent published reproductions.
  3. [3]The StructEd — "How to Calculate Balanced Snow Loads per ASCE 7-16". Reproduction used to read Table 7.3-1 in full (Terrain B 0.9 / 1.0 / 1.2; C 0.9 / 1.0 / 1.1; D 0.8 / 0.9 / 1.0; above treeline and treeless Alaska 0.7 / 0.8 / N/A), Table 7.3-2 (0.85 greenhouse, 1.0 standard, 1.1 cold ventilated with R above 25, 1.2 unheated, 1.3 freezer), Table 1.5-2 (Is 0.80 / 1.00 / 1.10 / 1.20 for Risk I–IV), and the §7.3.4 minimum rule.
  4. [4]Medeek Design Inc. — Snow Loads reference. Independent confirmation of Eq. 7.3-1 as pf = 0.7 Ce Ct Is pg and Eq. 7.4-1 as ps = Cs pf, and source of the snow density relation γ = 0.13 pg + 14 pcf with its 30 pcf maximum, which this page uses for the indicative depth figure.
  5. [5]STRUCTURE magazine — "ASCE 7-22 Flat Roof Snow Load Versus Minimum Snow Load". Source for the ASCE 7-22 changes named on the page: that 7-22's Eq. 7.3-1 drops the importance factor, that ground snow loads are obtained per site and risk category from the ASCE Hazard Tool at ascehazardtool.org, and that the minimum load must be evaluated as a separate uniform load case with a pm,max cap.
  6. [6]STRUCTURE magazine — "Snow Thermal Factors for Structural Renovations". Independent confirmation of the Table 7.3-2 thermal factor values (0.85 for certain greenhouses, 1.0 for heated structures, 1.1 for cold ventilated roofs, 1.2 for unheated structures, 1.30 for freezer buildings) and of the change to an R-value-based table in ASCE 7-22.
  7. [7]American Society of Civil Engineers — ASCE Hazard Tool. The authoritative source for the site-specific ground snow load pg that this page requires as an input and never assumes, including the identification of "case study" regions where no mapped value applies and the local jurisdiction's published value governs.

In this category

Embed

Quanta Pro

Paid features are coming later.

  • All 977 calculators remain free
  • No billing is enabled
Coming soon