Window U Factor Savings Calculator
Estimate yearly heat-loss and cost savings from lower-U-factor windows using window area, old and new U-factors, degree-hours and delivered heat cost.
Window U Factor Savings Calculator
Background.
The NFRC label on a new window gives its U-factor: how many Btu of heat pass through each square foot every hour for each degree Fahrenheit of difference between inside and outside. Lower is better. A single-pane window rates roughly 1.0, an older double-pane unit with clear glass around 0.5, and a modern double-pane window with a low-emissivity coating and gas fill around 0.3 or a little below. Turning that drop in U-factor into money takes three more numbers: how much window area you are replacing, how cold your climate is over a year, and what a unit of delivered heat costs you.
Climate enters as degree-hours. Each hour the outdoor temperature sits below a base temperature, conventionally 65 °F, counts as many degree-hours as there are degrees of difference. Weather services usually publish degree-days, the same measure summed by day, so multiply by 24 to convert: 5,000 heating degree-days is 120,000 degree-hours.
Multiplying the U-factor reduction by area and degree-hours gives the yearly reduction in heat conducted through the glass and frames, in Btu. Dividing by 3,412.142 Btu per kWh converts it to kWh, and the energy price you enter turns it into money.
The estimate covers conduction only. Replacing old windows also changes air leakage, often a larger effect with loose sashes, and solar heat gain, which can work for you or against you depending on orientation and season. Even a good window is a weak spot in a wall: a U-factor of 0.3 corresponds to an R-value of about 3.3.
What is window u factor savings calculator?
Window U-factor savings are the reduction in heat conducted through windows over a year when their U-factor is lowered, and the cost of the heating energy that no longer has to be supplied. U-factor is the rate of heat flow through the whole window, glass, spacer and frame together, per square foot per degree Fahrenheit, in Btu/(h·ft²·°F). In metric ratings it is given in W/(m²·K); dividing a metric value by 5.678 converts it to the US unit used here.
How to use this calculator.
- Enter the total area of the windows being replaced in square feet, using the rough-opening or frame size, since the U-factor on the label applies to the whole unit, frame included.
- Enter the existing U-factor, from an old label or a typical value for the window type, and the replacement's U-factor from its NFRC label or quote. Use the whole-window figure, not a centre-of-glass value.
- Enter annual degree-hours: heating degree-days for your location multiplied by 24. Cooling degree-hours can be added, but conduction is a small part of a window's summer heat gain, so heating degree-hours alone are the cleaner input.
- Enter the cost of one kWh of heat delivered into the house, not the price of fuel. For electric resistance heat that is the electricity price; for a heat pump, the electricity price divided by its seasonal COP; for a furnace, the fuel price per kWh of fuel divided by its efficiency.
The formula.
Heat saved Q = (U old − U new) × A × DH, where the U-factors are in Btu/(h·ft²·°F), A is window area in square feet and DH is annual degree-hours in °F·h, so Q is in Btu per year. Cost savings = Q ÷ 3,412.142 × c, where 3,412.142 is the number of Btu in one kWh and c is the cost of a delivered kWh of heat. If the new U-factor is not lower than the old one, the difference is taken as zero and the savings are zero rather than negative. The model assumes the indoor–outdoor temperature difference that degree-hours describe applies directly to the window, and that every Btu kept in replaces a Btu the heating system would have supplied. A 65 °F base overstates heating hours for a very well-insulated house, whose internal gains keep it warm to a lower outdoor temperature.
A worked example.
Replacing 250 square feet of windows rated U 0.5 with new ones rated U 0.3 lowers the U-factor by 0.2. In a climate with 5,000 heating degree-days, which is 120,000 degree-hours, the yearly reduction in conducted heat is 0.2 × 250 × 120,000 = 6,000,000 Btu. Dividing by 3,412.142 gives about 1,758.43 kWh of heat. At 16 cents per delivered kWh, the estimated annual conductive-loss cost savings are 1,758.43 × 0.16 = $281.35. Sixteen cents per delivered kWh is what electric resistance heating costs at an electricity price of 16 cents, because resistance heat turns every kWh into a kWh of heat. At that rate each $1,000 spent on the windows takes about 3.6 years of conduction savings to recover, before counting any gain from reduced drafts.
Frequently asked questions.
How do I work out the delivered cost per kWh for a gas furnace?
Why are the savings smaller with a heat pump?
What if I am replacing single-pane windows?
Does this include savings from fewer drafts?
Can low-e windows increase my heating bill?
Can I use cooling degree-hours to estimate summer savings?
References& sources.
How this page was produced
- Published by
- Quanta Calculator
- Overseen by
- Daniel, Quanta Calculator Researcher
- Primary sources
- 3 cited below
- Method
- annual conductive heat-loss reduction = (old U − new U) × window area × degree-hours; cost uses entered delivered-energy price