Radiation Converter — Gy/rad, Sv/rem and Bq/Ci

Convert radiation units within one quantity: gray and rad, sievert and rem, becquerel and curie, using exact factors. Gray and sievert are never mixed.

Radiation Unit Converter

Radiation quantity
From unit
To unit
Converted value
25
The value expressed in the To unit, within the chosen quantity.
Conversion
250 mGy = 25 rad
SI value
0.25
SI unit
Gy
Quantity
Absorbed dose

Background.

Gray and sievert both work out to a joule per kilogram, yet a gray is not a sievert, and a converter that turned one into the other would be wrong in a way that matters. Radiation is described by three separate quantities, each with an SI unit and an older unit still common in American hospitals, labs and regulations: activity in becquerels or curies, absorbed dose in grays or rads, and equivalent dose in sieverts or rems. Within a quantity the conversion is exact arithmetic. Between quantities it is not a unit change at all. So the first choice here is the quantity, and the From and To menus then offer only its units; switch the quantity and both menus change with it.

The factors are set by definition. A rad is exactly 0.01 Gy and a rem exactly 0.01 Sv, so a gray is 100 rad and a sievert 100 rem. A curie is exactly 3.7 × 10¹⁰ Bq, which makes a millicurie 37 MBq and a microcurie 37 kBq. Each result also shows the value in the quantity's SI unit and a line repeating both units.

A converted number is the same measurement written differently. It carries no judgement about risk and is not a clinical interpretation or a regulatory assessment. Questions about a medical exposure belong with the treating clinician or a medical physicist, and workplace decisions with the licensed radiation-protection programme and its regulator.

What is radiation unit converter?

Activity is the rate at which a radioactive sample decays: one becquerel is one nuclear transformation per second, and the curie was originally tied to the activity of about one gram of radium-226. Absorbed dose is the energy ionising radiation deposits per unit mass of material: one gray is one joule per kilogram, and the older rad is 100 ergs per gram, or 0.01 Gy. Equivalent dose is absorbed dose multiplied by a radiation weighting factor that reflects how much biological harm each kind of radiation does, 1 for X-rays and gamma rays and 20 for alpha particles, and is expressed in sieverts or rem. The SI Brochure gives the gray and the sievert separate names so that the two are never confused.

How to use this calculator.

  1. Under "Radiation quantity", choose what the number measures: absorbed dose for Gy or rad, equivalent dose for Sv or rem, radioactivity for Bq or Ci. A personal dosimeter report is normally in mSv or mrem, while a source or vial label is in MBq or mCi.
  2. Enter the value; it can be zero or more.
  3. Choose the From and To units. If a unit you expect is missing from the menus, the quantity is set wrong.
  4. Millirem is not listed: 1 mrem is 0.01 mSv, or 0.001 rem, so convert it to one of those first.
  5. Read the converted value with the SI value and the statement line, and copy the quantity name along with the number into any record.

The formula.

target = value × SIper(source) ÷ SIper(target)

Each quantity has its own table of factors, each factor saying how many SI units one of that unit contains: target = value × SI-per(source) ÷ SI-per(target). For absorbed dose the factors are 1 for Gy, 0.001 for mGy, 0.000001 for µGy and 0.01 for rad. Equivalent dose follows the same pattern for Sv, mSv, µSv and rem. For activity they are 1 for Bq, 10³ for kBq, 10⁶ for MBq, 10⁹ for GBq, 3.7 × 10¹⁰ for Ci, 3.7 × 10⁷ for mCi and 3.7 × 10⁴ for µCi. All of these are exact definitions listed in NIST Special Publication 811, and the US Nuclear Regulatory Commission defines the same units in 10 CFR Part 20, so a conversion adds no uncertainty to the original figure.

A unit that is not in the chosen quantity's table is refused, which is what stops a gray-to-sievert request: with absorbed dose selected, Sv is simply not an absorbed-dose unit. Results are shown to ten decimal places. That is ample for doses, but a very small activity expressed in curies can fall below it, so tiny activities are better converted to microcuries.

A worked example.

Example

A dosimetry report gives an absorbed dose of 250 mGy, and the older protocol it is being compared with works in rad. With Absorbed dose selected and the units set to mGy and rad, the value first becomes grays: 250 × 0.001 = 0.25 Gy, shown as the SI value. Dividing by 0.01, the number of grays in one rad, gives 0.25 ÷ 0.01 = 25 rad, and the statement reads 250 mGy = 25 rad. Since a gray is 100 rad, a milligray is 0.1 rad, so any milligray figure divided by 10 gives rad directly. The 25 rad is still an absorbed dose. Calling it 25 rem would assume a radiation weighting factor of 1, which holds for X-rays and gamma rays but has to come from knowing the radiation, not from the units.

quantityabsorbedDose
to Unitrad
value250
from UnitmGy

Frequently asked questions.

Why won't it convert gray to sievert?
Because the step from gray to sievert is a physical model, not a unit factor. Equivalent dose is absorbed dose multiplied by a radiation weighting factor: 1 for X-rays and gamma rays, so 2 Gy of gamma corresponds to 2 Sv, but 20 for alpha particles, so the same 2 Gy from alpha emitters corresponds to 40 Sv. Only someone who knows the radiation can apply that factor.
How do I convert microsieverts to millirem?
Go through rem. With Equivalent dose selected, 350 µSv converts to 0.035 rem, and multiplying by 1,000 gives 35 mrem. The shortcut is that 1 mrem equals 10 µSv, so dividing a microsievert figure by 10 gives millirem, and 1 mSv equals 100 mrem.
Why does a small activity come out as 0 Ci?
One becquerel is about 2.7 × 10⁻¹¹ Ci, smaller than the ten decimal places shown, so 1 Bq converted to curies displays as 0, and a few becquerels lose most of their digits. Convert to microcuries instead: 1,000 Bq is about 0.027 µCi, shown with plenty of significant figures.
If I know a source's activity, can I work out the dose?
Not with a unit conversion. The dose from a source depends on which radionuclide it is, the type and energy of its emissions, distance, shielding and exposure time, and for material taken into the body on how long it stays and where it goes. Two sources of the same activity in becquerels can give very different doses.
Where does the curie's odd value come from?
It was originally set by the activity of about one gram of radium-226, the element Marie and Pierre Curie discovered, and was later fixed at exactly 3.7 × 10¹⁰ decays per second, now 3.7 × 10¹⁰ Bq. That is why the conversions involve 37: 10 mCi is 370 MBq, and 1 GBq is about 27.03 mCi.
Can I convert an effective dose here?
Yes, using the Equivalent dose setting. Effective dose is a weighted sum of the equivalent doses to different organs, but it is expressed in the same units, sieverts or rem, with the same factor between them. So an effective dose of 5 rem converts to 50 mSv exactly as an equivalent dose would.
Why are roentgens not included?
The roentgen measures a fourth quantity, exposure, the ionisation X-rays or gamma rays produce in air, defined as 2.58 × 10⁻⁴ coulombs per kilogram of air. It is not an activity, an absorbed dose or an equivalent dose, and the rough rules of thumb linking roentgens to rads depend on the radiation energy and the material, so no exact conversion exists.

How this page was produced

Published by
Quanta Calculator
Primary sources
3 cited below
Method
target = value × SIper(source) ÷ SIper(target)
Published
Last verified