Heat Transfer Coefficient Calculator

Back-calculate a heat-transfer coefficient in W/(m²·K) from a measured heat rate, the area it crosses and the temperature difference driving it.

Heat Transfer Coefficient Calculator

W
m²
K
Effective heat-transfer coefficient
15
The effective heat-transfer coefficient in W/(m²·K): watts crossing each square metre for every kelvin of temperature difference.
Model scope
Effective coefficient from stated measurements; it does not distinguish convection from an overall U value, select local/mean ΔT, or infer radiation, fouling, geometry, flow regime, and property variation.

Background.

Stand in a breeze on a cool day and you lose heat faster than in still air at the same temperature. That difference, how readily heat crosses between a surface and a fluid for each degree of temperature gap, is what a heat-transfer coefficient measures. Still air is a poor carrier: the typical-values table in Incropera's heat-transfer textbook puts free convection in gases at 2 to 25 W/(m²·K). Blow the air and the range becomes 25 to 250; pump a liquid past the surface and it runs from 100 to 20,000; boiling or condensing fluids reach 2,500 to 100,000.

Predicting a coefficient from first principles is hard. Correlations for each geometry and flow are approximate, so engineers often work the other way round and measure: supply a known heat rate, measure the area and the temperature difference, and divide. That back-calculation is what happens here.

The result is an effective coefficient. It contains everything that happened between the two temperatures you measured. Across a heated panel in a room, that includes radiation as well as convection. Across a heat-exchanger tube, it includes both fluid films, the metal wall and any scale or deposit, which makes it an overall U value rather than a single film coefficient. Which of these you have depends entirely on where the temperatures were taken, and the arithmetic cannot tell them apart.

That is also what makes it a good diagnostic. An exchanger whose measured coefficient drifts down month after month is fouling, and plotting the figure over time shows when cleaning will pay for itself. A test rig that returns a value far outside the expected range more often has a misplaced thermocouple or an uncounted heat loss than new physics.

What is heat transfer coefficient calculator?

A heat-transfer coefficient is the rate of heat flow per unit area per kelvin of temperature difference, in watts per square metre per kelvin, W/(m²·K). A convection coefficient h describes one surface and the fluid moving past it; an overall coefficient U describes the full path through a wall or exchanger from one fluid to another. Both share the unit and the defining equation, and the reciprocal, 1/h or 1/U, is a thermal resistance per unit area in m²·K/W.

How to use this calculator.

  1. Enter the heat-transfer rate in watts, measured once conditions are steady. For an electric heater it is the power drawn; for a fluid stream it is mass flow × specific heat × that stream's temperature change.
  2. Enter the area heat actually crosses, in square metres. For a tube, choose the inside or the outside surface and stick with it, because the coefficient changes with that choice.
  3. Enter the temperature difference in kelvin; a difference in °C is the same number, and one in °F should be divided by 1.8. For a surface in a fluid, use surface temperature minus bulk fluid temperature; for a heat exchanger, use the log-mean temperature difference.
  4. Compare the result with the range expected for your situation, remembering that it includes radiation and any other path between your two measuring points.

The formula.

h = Q̇ / (AΔT)

h = Q̇ ÷ (A × ΔT), where Q̇ is the heat-transfer rate in watts, A the area in square metres and ΔT the temperature difference in kelvin. It is Newton's law of cooling, Q̇ = h × A × ΔT, rearranged to give the coefficient. The coefficient rises in direct proportion to the heat rate and falls in inverse proportion to both area and temperature difference, so a 10% error in any one input becomes an error of roughly 9 to 10% in h. The temperature difference is usually the weakest link: with only 10 K between surface and fluid, a thermocouple reading one degree off shifts the coefficient by about 10%. All three inputs must be positive. Nothing here predicts h from fluid properties or flow speed; correlations built on Reynolds, Prandtl and Nusselt numbers do that, and measured coefficients are what those correlations are tested against. The result is rounded to 12 significant figures.

A worked example.

Example

An electrically heated panel draws 1,500 W at steady state, has 5 m² of surface and sits 20 K warmer than the surrounding air. The area times the temperature difference is 5 × 20 = 100 m²·K, and 1,500 ÷ 100 = 15 W/(m²·K). That falls inside the 2 to 25 W/(m²·K) typical of free convection in gases, which suits a panel in still room air, but the measured figure also carries radiation. For a high-emissivity surface (ε = 0.9) near 300 K, the linearised radiation coefficient 4εσT³ comes to about 5.51 W/(m²·K), leaving roughly 9.49 for convection itself. Had the same 1,500 W held the panel only 10 K above the air, the coefficient would be 30 W/(m²·K), a sign of a draught or fan.

transfer Area M25
heat Transfer Rate W1,500
temperature Difference K20

Frequently asked questions.

Have I measured a convection coefficient h or an overall U value?
It depends on where your two temperatures were taken. Surface temperature and fluid temperature give a film coefficient h for that surface. Fluid temperatures on both sides of a wall or tube give an overall U, which combines both films, the wall and any fouling into one figure.
How much does it matter which temperature difference I use for a heat exchanger?
A lot when the ends differ. With 60 K at one end and 10 K at the other, the log-mean difference is about 27.9 K but the simple average is 35 K, so using the average gives a coefficient about 20% too low. When both ends are similar, the two agree closely.
My result seems high for still air. What could be inflating it?
Radiation is the usual cause, worth roughly 5 to 6 W/(m²·K) for a dull surface near room temperature. Heat escaping through mountings or the back face also counts in the measured power without adding to the area, and a draught you have not noticed raises the convection itself.
How do I convert W/(m²·K) to Btu per hour per square foot per °F?
Divide by about 5.678, because 1 Btu/(h·ft²·°F) equals roughly 5.678 W/(m²·K). The page's example of 15 W/(m²·K) is therefore about 2.64 Btu/(h·ft²·°F). If your temperature difference was in °F, convert it to kelvin first by dividing by 1.8.
Why would a measured coefficient fall over time?
In heat exchangers the usual reason is fouling: scale, biological growth or sediment builds an extra insulating layer on the surfaces. Each layer adds thermal resistance in series, so the overall coefficient drops, and tracking it is a standard way to schedule cleaning.
How does the coefficient relate to an R-value?
Its reciprocal is a thermal resistance per unit area. A coefficient of 15 W/(m²·K) corresponds to about 0.0667 m²·K/W, which is how surface films are entered when a wall's layer resistances are added up to find its overall R-value and U-value.

How this page was produced

Published by
Quanta Calculator
Primary sources
3 cited below
Method
h = Q̇ / (AΔT)
Published
Last verified

Built with AI assistance and verified by automated tests against the cited sources — every worked example on this page is computed by the same code that runs the calculator. How we build and check calculators.